Description
| BW-Technologies by Honeywell | GasAlertMax XT II Specifications | |||||||
| Size | 5.1 x 2.8 x 2.0 in. / 13.1 x 7.0 x 5.2 cm | |||||||
| Weight | 11.5 oz. / 328 g | |||||||
| Temperature | -4 to 122ºF / -20 to 50ºC | |||||||
| Humidity | 10 – 100% RH (non-condensing) | |||||||
| Alarms |
– Visual, vibrating, audible (95dB)
– Low, High, STEL, TWA, OL (over limit), Low Battery, Pump
|
|||||||
| Tests |
Audible/visual alarms on activation, sensors, battery, pump
and circuitry (continuous) |
|||||||
| Typical battery life |
13 hours @ 32ºF / 0ºC
8 hours @ -4ºF / -20ºC Recharges in 6 hours |
|||||||
| Pump draw |
Sample from up to 75 ft. / 23 m
|
|||||||
| User options |
Confidence beep
|
Force calibration when overdue
|
||||||
|
Safety (sensor) lock
|
Sensor configuration
|
|||||||
|
Latching alarms
|
Detector identification
|
|||||||
|
Safe display mode
|
Low alarm acknowledge
|
|||||||
|
Calibration IR lock
|
Language choices (five)
|
|||||||
|
Location selection
|
Set custom start-up message
|
|||||||
|
Force block test
|
Confidence interval
|
|||||||
|
Force bump test when overdue
|
Datalog interval
|
|||||||
| Ratings Ingress Protection |
EMI/RFI: Complies with EMC Directive 2004/108/EC
IP66/67 |
|||||||
| Certifications and approvals |
![]() Class I, Div. 1, Gr. A, B, C, D
|
|||||||
|
IECEx: Ga Ex ia IIC T4
|
||||||||
|
ATEX:
![]() |
||||||||
|
Br Ex ia IIC T4
|
||||||||
| Warranty |
Full two year warranty including all sensors
|
|||||||
| GAS |
Measuring Range
|
Resolution
|
|
| H2S |
0-200 ppm
|
1 ppm
|
|
| CO |
0-1000 ppm
|
1 ppm
|
|
| O2 |
0-30.0%
|
0.1%
|
|
| Combustible gases |
0-100% LEL
0-5.0% v/v |
1%
0.1% |
|
| Alarm setpoints for all sensors are user adjustable. Setpoint(s) are automatically displayed during instrument start-up. | |||
• Continuous LCD shows real-time gas concentrations
• Compact and lightweight design makes it comfortable to wear
• Water-resistant
• Simple automatic calibration procedure; compatible with BW MicroDock II automatic test and calibration station
• Full function self-test of sensor, battery status, circuit integrity and audible/visual alarms on start up
• Bright wide-angled visual alarm bars
• Built-in concussion-proof boot
• Integrated sampling pump with reliable diaphragm technology
• Best in class block detection with semi-conductor pressure sensor
• Multi-language support in English, French, German, Spanish and Portuguese
• Conveniently manage your detector with Fleet Manager II
• Equipped with standard datalogging and event logging