Description
| BW-Technologies
by Honeywell |
GasAlertMicroClip XL Multi-Gas Detector Specifications | |||||||
| Size | 4.4 x 2.4 x 1.2 in. / 11.3 x 6.0 x 3.2 cm | |||||||
| Weight | 6.7 oz. / 190 g | |||||||
| Temperature | -4 to +122°F / -20 to +50°C | |||||||
| Humidity | 0% – 95% RH (non-condensing) | |||||||
| Alarms |
Visual, vibrating, audible (95 dB) • Low, High, STEL, OL (over limit)
|
|||||||
| Tests |
Audible/visual alarms on activation; sensors, battery and circuitry (continuous)
|
|||||||
| Typical battery life |
18 hours; recharges in less than 6 hours
Note: Approximately 20% capacity loss is normal with lithium polymer batteries after 500 charge cycles. Refer to the Operator’s Manual for additional information. |
|||||||
| User options |
Confidence beep
|
IntelliFlash™ interval
|
||||||
|
Set STEL interval
|
Combustible gas
|
|||||||
|
Sensor on/off
|
measurement (%LEL or % by volume methane)
|
|||||||
|
Latching alarms
|
User-settable calibration
|
|||||||
|
Safe display mode
|
gas level
|
|||||||
|
Stealth mode
|
Force calibration
|
|||||||
|
Calibration lock
|
when overdue
|
|||||||
|
Auto zero on start up
|
Low alarm acknowledge
|
|||||||
|
O2 auto calibration
|
Language choices
|
|||||||
|
on start up
|
Set custom start up message
|
|||||||
|
Set bump test interval
|
||||||||
|
Force bump test when overdue
|
||||||||
| Ratings | IP68 EMI/RFI: Complies with EMC Directive 2004/108/EC |
|||||||
| Certifications and approvals |
![]() Class I, Div. 1, Gr. A, B, C, D
|
|||||||
|
IECEx: Ex ia IIC T4 Ga
|
||||||||
|
ATEX:
![]() Ex ia IIC T4 Ga
|
||||||||
European Conformity |
||||||||
| Warranty |
Full two‑year (GasAlertMicroClip XL) or three‑year (GasAlertMicroClip X3) warranty including all sensors
Note: Battery is guaranteed to have 12 hour runtime during warranty period under normal operating temperature of 4°F / -20°C to 122°F / 50°C. |
|||||||
| GAS |
Measuring Range
|
Resolution
|
|
| H2S |
0-100 ppm
|
1 ppm
|
|
| CO |
0-500 ppm
|
1 ppm
|
|
| O2 |
0-30.0%
|
0.1%
|
|
| Combustible gases |
0-100% LEL
0-5.0% v/v |
1%
0.1% |
|
| Alarm setpoints for all sensors are user adjustable. Setpoint(s) are automatically displayed during instrument start-up. | |||
DUE TO ONGOING RESEARCH AND PRODUCT IMPROVEMENT, SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
• Guaranteed runtime for at least a 12-hour shift — down to -20°C — without compromising LEL detection of hydrogen, acetylene and other combustible gases
• Durable, rechargeable lithium polymer battery — tested to last in extreme environments
• Ergonomic and wearable — doesn’t weigh you down
• Real-time gas concentrations shown on LCD
• Bright, wide-angle visual alarm bars
• IP68 rating ensures maximum protection against dust and water
• User-friendly, tamper-proof operation with just one button and intuitive LCD icons
• IntelliFlash™ light indicating detector has been bump tested and is monitoring correctly
• Self-test of sensors, battery status, circuit integrity and audible/visual alarms on startup
• Compatible with MicroDock II docking station for automated bump tests and calibration
• Compatible with Fleet Manager II software for reporting and fleet management
• Multi-language support in English, French, German, Spanish and Portuguese
Use our unique advanced technology for safety, compliance and productivity.
• Advanced engineering for reliable battery performance
• Reflex Technology™ automated self-test function routinely checks the operating condition of the sensors to increase safety, up-time, and overall worker confidence
• Compact, lightweight and easy to use — no expertise required
• Flashing green IntelliFlash™ light for compliance at a glance